 |
 |
| Valve systems |
 |
 |
 | Valve system, Series HF04-XF
|
▶ Qn Max. = 400 l/min ▶ Multipole ▶ Electr. connection: D-Sub plug, 25-pin, on the side / D-Sub plug, 44-pin, on the side
| |
 | Valve system, Series HF04-XF
|
▶ Qn Max. = 400 l/min ▶ Direct field bus connection (BDC) ▶ B-design
| |
 | Valve system, Series HF04-XF
|
▶ Qn Max. = 400 l/min ▶ Optional field bus connection with I/O function (CMS) ▶ B-design
| |
 | Valve system, Series HF04-XF
|
▶ Qn Max. = 400 l/min ▶ Connection with diagnosis (DDL) ▶ B-design
| |
 | Valve system, Series HF04-XF
|
▶ Qn Max. = 400 l/min ▶ Connection with diagnosis, optionally with I/O function (DDL) ▶ B-design
| |
 | Valve system, Series HF04-XF
|
▶ Qn Max. = 400 l/min ▶ Field bus connection with AS i ▶ B-design
| |
 |
| Valves |
 |
 |
 | 2x3/2-way valve, Series HF04 and LP04
|
▶ Qn = 400 l/min ▶ plate connection ▶ Manual override: with detent
| |
 | 2x3/2-way valve, Series HF04 and LP04
|
▶ Qn = 400 l/min ▶ plate connection ▶ Manual override: without detent
| |
 | 5/2-way valve, Series HF04 and LP04
|
▶ Qn = 400 l/min ▶ plate connection ▶ Manual override: with detent ▶ single solenoid, double solenoid
| |
 | 5/2-way valve, Series HF04 and LP04
|
▶ Qn = 400 l/min ▶ plate connection ▶ Manual override: without detent ▶ single solenoid, double solenoid
| |
 | 5/3-way valve, Series HF04 and LP04
|
▶ Qn = 400 l/min ▶ closed center ▶ plate connection ▶ Manual override: with detent
| |
 | 5/3-way valve, Series HF04 and LP04
|
▶ Qn = 400 l/min ▶ closed center ▶ plate connection ▶ Manual override: without detent
| |
 |
| Accessories |
 |
 |
| Field Bus Modules |
 |
 |
 | Direct field bus connection (BDC), B-design
|
▶ Bus module with driver ▶ Field bus protocol: PROFIBUS DP / CANopen / CANopen sb / DeviceNet / sercos III
| |
 | Optional field bus connection with I/O function (CMS), B-design
|
▶ Bus module with driver ▶ Field bus protocol: PROFIBUS DP / DeviceNet / CANopen / Interbus S / EtherNET/IP
| |
 | Field bus connection with I/O functionality (CMS), B-design
|
▶ Bus module with driver ▶ Field bus protocol: PROFINET IO
| |
 | Connection with diagnosis (DDL), B-design
|
▶ Driver
| |
 | Connection with diagnosis, optionally with I/O function (DDL), B-design
|
▶ Driver
| |
 | Field bus connection with AS i, B-design
|
▶ Bus module with driver ▶ Field bus protocol: AS-i
| |
 | Field bus connection with AS i, B-design
|
▶ Bus module with driver ▶ Field bus protocol: AS i with inputs
| |
 |
| Other accessories |
 |
 |
 | Pressure regulator subplate, Series HF04, HF04-XF and LP04
|  | |
 | Multipole plug D-Sub (25-pin)
|
▶ Socket, D-Sub, 25-pin
| |
 | Multipole plug (44-pin)
|
▶ Socket, D-Sub, 44-pin ▶ high density
| |
 | Multipole plug (44-pin)
|
▶ Socket, D-Sub, 44-pin
| |
 | HF04-XF, CKD kit metric
|
▶ compressed air connection output: Ø 6 ▶ Can be assembled into blocks ▶ Double base plate principle ▶ Reversed pressure supply permissible ▶ Bus module extension possible ▶ I/O extension possible ▶ With collective pilot air exhaust
| |
 | Blanking plate, Series HF04, HF04-XF
|  | |
 | Accessories, Series HF04-XF
|  | |
 |